{"id":50622,"date":"2019-09-25T16:20:37","date_gmt":"2019-09-25T16:20:37","guid":{"rendered":"https:\/\/vizir.az\/?page_id=50622"},"modified":"2019-09-30T06:47:08","modified_gmt":"2019-09-30T06:47:08","slug":"1-to-4-guardsman-lb-lj-and-lsj-series","status":"publish","type":"page","link":"https:\/\/vizir.az\/az\/1-to-4-guardsman-lb-lj-and-lsj-series\/","title":{"rendered":"1&#8243; to 4&#8243; Guardsman LB, LJ, and LSJ Series"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ultimate-heading-888969f39e07ccab9\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-888969f39e07ccab9 uvc-403  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-888969f39e07ccab9 h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;\">1\" to 4\" Guardsman LB, LJ, and LSJ Series<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Smith Meter\u00ae Guardsman&#x2122; LB, LJ, and LSJ Series Turbine Meters are rimless-type rotor meters which utilize an upstream stator to support the rotor. They are intended for use at loading racks to provide the highly accurate measurement required for custody transfer of petroleum liquids.<\/p>\n<p>Options:<\/p>\n<ul>\n<li>Dual Pickup Coils \u2013 Used when pulse security is required.<\/li>\n<li>Turbine Meter Diagnostic when used with AccuLoad III (see application bulletin AB06061.<\/li>\n<\/ul>\n<p>Operating Specifications:<\/p>\n<p>Linearity \u00b10.25% and \u00b10.15%.<\/p>\n<p>Meter Sizes \u2013 from 1\u201d to 4\u201d.<\/p>\n<p>Flow Range \u2013 from 30 L\/min h to 4500 L\/min.<\/p>\n<p>Maximum Working Pressure \u2013 from 1965 kPa to 5102 kPa.<\/p>\n<p>Meter Operating Temperature Range \u2013 from -29\u00baC to 107\u00baC.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"295\" height=\"300\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1to4GuardsmanLBLJandLSJSeries-295x300.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"1to4GuardsmanLB,LJ,andLSJSeries\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1to4GuardsmanLBLJandLSJSeries-295x300.jpg 295w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1to4GuardsmanLBLJandLSJSeries-768x782.jpg 768w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1to4GuardsmanLBLJandLSJSeries.jpg 823w\" sizes=\"auto, (max-width: 295px) 100vw, 295px\"  data-dt-location=\"https:\/\/vizir.az\/az\/liquid-flow-measurement\/turbine-meters\/guardsman-series\/1to4guardsmanlbljandlsjseries\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div id=\"ultimate-heading-934369f39e07ce023\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-934369f39e07ce023 uvc-3640  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-934369f39e07ce023 h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">1\" to 4\" Guardsman LB, LJ, and LSJ Series<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/2b_ss02003-1.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/az\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1&#8243; to 4&#8243; Guardsman LB, LJ, and LSJ Series Smith Meter\u00ae Guardsman&#x2122; LB, LJ, and LSJ Series Turbine Meters are rimless-type rotor meters which utilize an upstream stator to support the rotor. They are intended for use at loading racks to provide the highly accurate measurement required for custody transfer of petroleum liquids. Options: Dual&hellip;<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-50622","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/50622","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/comments?post=50622"}],"version-history":[{"count":2,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/50622\/revisions"}],"predecessor-version":[{"id":51530,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/50622\/revisions\/51530"}],"wp:attachment":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/media?parent=50622"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}