{"id":50785,"date":"2019-09-26T05:41:18","date_gmt":"2019-09-26T05:41:18","guid":{"rendered":"https:\/\/vizir.az\/?page_id=50785"},"modified":"2019-09-30T06:08:42","modified_gmt":"2019-09-30T06:08:42","slug":"model-de-1-vde-1-and-de-2-air-release-heads","status":"publish","type":"page","link":"https:\/\/vizir.az\/az\/model-de-1-vde-1-and-de-2-air-release-heads\/","title":{"rendered":"Model DE-1, VDE-1 and DE-2 Air Release Heads"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ultimate-heading-863569dbaef8ce8ea\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-863569dbaef8ce8ea uvc-5749  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-863569dbaef8ce8ea h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;\">Model DE-1, VDE-1 and DE-2 Air Release Heads<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>The Smith Meter\u00ae Model DE Air Release Heads are dual-electric float switch devices for installation on air eliminator vessels. The dual floats provide a unique and efficient method of air elimination from liquids, as is essential for accurate metering. Air is gathered in the vessel until the lower float switch is actuated. This causes the air vent solenoid valve to open and signals the block valve downstream of the meter to close. The flow is blocked until sufficient air is eliminated from the vessel to actuate the upper float by liquid. This causes the air vent solenoid valve to close and signals the block valve to open, resuming flow. The DE Head is intended to be used in metering systems where bulk air is particularly troublesome (e.g., unloading off tank trucks and barges, or stripping tanks).<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"182\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/Model-DE-1-VDE-1-and-DE-2-Air-Release-Heads-300x182.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"Model DE-1, VDE-1 and DE-2 Air Release Heads\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/Model-DE-1-VDE-1-and-DE-2-Air-Release-Heads-300x182.jpg 300w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/Model-DE-1-VDE-1-and-DE-2-Air-Release-Heads-768x467.jpg 768w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/Model-DE-1-VDE-1-and-DE-2-Air-Release-Heads-1024x622.jpg 1024w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/Model-DE-1-VDE-1-and-DE-2-Air-Release-Heads.jpg 1312w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\"  data-dt-location=\"https:\/\/vizir.az\/az\/model-de-1-vde-1-and-de-2-air-release-heads-2\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div id=\"ultimate-heading-926069dbaef8d06de\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-926069dbaef8d06de uvc-4465  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-926069dbaef8d06de h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">Model DE-1, VDE-1 and DE-2 Air Release Heads<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/16_ss03030.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/az\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Model DE-1, VDE-1 and DE-2 Air Release Heads The Smith Meter\u00ae Model DE Air Release Heads are dual-electric float switch devices for installation on air eliminator vessels. The dual floats provide a unique and efficient method of air elimination from liquids, as is essential for accurate metering. Air is gathered in the vessel until the&hellip;<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-50785","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/50785","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/comments?post=50785"}],"version-history":[{"count":2,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/50785\/revisions"}],"predecessor-version":[{"id":51511,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/50785\/revisions\/51511"}],"wp:attachment":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/media?parent=50785"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}