{"id":51297,"date":"2019-09-28T18:14:03","date_gmt":"2019-09-28T18:14:03","guid":{"rendered":"https:\/\/vizir.az\/?page_id=51297"},"modified":"2019-10-20T10:54:28","modified_gmt":"2019-10-20T10:54:28","slug":"rpm4-reference-pressure-monitor","status":"publish","type":"page","link":"https:\/\/vizir.az\/az\/calibrators\/pressure-calibrators\/rpm4-reference-pressure-monitor\/","title":{"rendered":"RPM4 Reference Pressure Monitor"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ultimate-heading-21866ab23ec2e60ea\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-21866ab23ec2e60ea uvc-549  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-21866ab23ec2e60ea h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;\">RPM4 Reference Pressure Monitor<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Premium performance in a compact and rugged reference pressure monitor RPM4 is much more than a traditional pressure indicator. State of the art performance from very low pressure to 280 MPa. Infinite Ranging gives RPM4 unprecedented versatility in adapting to the specific range of operation.<\/p>\n<ul>\n<li>Independent quartz reference pressure transducer modules with individual self-defense systems.<\/li>\n<li>Differential measurement mode (channel 1- channel 2).<\/li>\n<li>15 kPa compound gauge Q-RPT with turndown to &lt; 3 kPa.<\/li>\n<li>Battery\/charger pack available.<\/li>\n<li>User defined pressure units.<\/li>\n<li>Large character, easy to read display.<\/li>\n<li>12 V dc power and battery pack option.<\/li>\n<li>RS232 and IEEE-488 communications.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"201\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/PCAL-RMP4_01a_328px_x_220px-300x201.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"PCAL-RMP4_01a_328px_x_220px\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/PCAL-RMP4_01a_328px_x_220px-300x201.jpg 300w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/PCAL-RMP4_01a_328px_x_220px.jpg 328w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\"  data-dt-location=\"https:\/\/vizir.az\/az\/calibrators\/pressure-calibrators\/rpm4-reference-pressure-monitor\/pcal-rmp4_01a_328px_x_220px\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div id=\"ultimate-heading-30126ab23ec2e77b1\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-30126ab23ec2e77b1 uvc-3965  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-30126ab23ec2e77b1 h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">RPM4 Reference Pressure Monitor<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/12_RPM4-Reference-Pressure-Monitor.pdf\" target=\"\"  class=\"vc_single_image-wrapper\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/az\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/12a_3031143C_w.pdf\" target=\"\"  class=\"vc_single_image-wrapper\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/az\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>RPM4 Reference Pressure Monitor Premium performance in a compact and rugged reference pressure monitor RPM4 is much more than a traditional pressure indicator. State of the art performance from very low pressure to 280 MPa. Infinite Ranging gives RPM4 unprecedented versatility in adapting to the specific range of operation. Independent quartz reference pressure transducer modules&hellip;<\/p>","protected":false},"author":3,"featured_media":0,"parent":51207,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-51297","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/51297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/comments?post=51297"}],"version-history":[{"count":1,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/51297\/revisions"}],"predecessor-version":[{"id":51299,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/51297\/revisions\/51299"}],"up":[{"embeddable":true,"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/pages\/51207"}],"wp:attachment":[{"href":"https:\/\/vizir.az\/az\/wp-json\/wp\/v2\/media?parent=51297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}