{"id":50835,"date":"2019-09-26T10:23:22","date_gmt":"2019-09-26T10:23:22","guid":{"rendered":"https:\/\/vizir.az\/?page_id=50835"},"modified":"2019-10-19T19:53:43","modified_gmt":"2019-10-19T19:53:43","slug":"dfm-6-1-doppler-flow-meter","status":"publish","type":"page","link":"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/water-wastewater-flow-meter\/ultrasonic-flow-meters-2\/dfm-6-1-doppler-flow-meter\/","title":{"rendered":"DFM 6.1 Doppler Flow Meter"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ultimate-heading-699069d523052a649\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-699069d523052a649 uvc-3083  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-699069d523052a649 h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;\">DFM 6.1 Doppler Flow Meter<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Measure flow from outside a pipe. The Greyline DFM 6.1 is designed for &#8220;difficult liquids&#8221; that would damage regular flow meters &#8211; wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. There is no obstruction to flow and no pressure drop. The non-intrusive, clamp-on ultrasonic sensor fits any pipe 1\/2&#8243; (12.5 mm) Inside Diameter or larger. The DFM 6.1 features enhanced performance in a wide range of applications. Improved industrial noise immunity filters potential interference souces.<\/p>\n<p>Use the isolated 4-20mA output to transmit flow to remote displays, recorders or controllers. The programmable relays can be used for flow control, pump protection or flow proportionate pulse. Calibration is easy with the built-in 5-key calibrator. Display and totalize flow in your choice of engineering units (gallons, liters etc). A 128MB data logger is standard, capable of capturing up to 26 million data points. Optional MODBUS RTU via HART is available for connection to automation systems.<\/p>\n<p>Sensor cable can be extended up to 500 ft. (152 m) with no loss of signal. The standard sensor is rated non-incendive for Class I, Division 2 hazardous locations and the DFM 6.1 can be equipped with optional Intrinsic Safety Barriers for sensor installation in Class I, Division I hazardous locations.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"269\" height=\"300\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/DFM-6.1-Doppler-Flow-Meter-1-269x300.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"DFM 6.1 Doppler Flow Meter\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/DFM-6.1-Doppler-Flow-Meter-1-269x300.jpg 269w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/DFM-6.1-Doppler-Flow-Meter-1-768x857.jpg 768w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/DFM-6.1-Doppler-Flow-Meter-1-917x1024.jpg 917w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/DFM-6.1-Doppler-Flow-Meter-1.jpg 1659w\" sizes=\"auto, (max-width: 269px) 100vw, 269px\"  data-dt-location=\"https:\/\/vizir.az\/ru\/dfm-6-1-doppler-flow-meter-3\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div id=\"ultimate-heading-78969d523052b53c\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-78969d523052b53c uvc-8720  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-78969d523052b53c h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">DFM 6.1 Doppler Flow Meter<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1_DFM-6.1-Brochure.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>DFM 6.1 Doppler Flow Meter Measure flow from outside a pipe. The Greyline DFM 6.1 is designed for &#8220;difficult liquids&#8221; that would damage regular flow meters &#8211; wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. There is no obstruction to flow and no pressure drop. The non-intrusive, clamp-on ultrasonic sensor fits any pipe 1\/2&#8243; (12.5&hellip;<\/p>","protected":false},"author":3,"featured_media":0,"parent":50824,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-50835","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50835","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/comments?post=50835"}],"version-history":[{"count":1,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50835\/revisions"}],"predecessor-version":[{"id":50859,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50835\/revisions\/50859"}],"up":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50824"}],"wp:attachment":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/media?parent=50835"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}