{"id":50881,"date":"2019-09-26T10:49:46","date_gmt":"2019-09-26T10:49:46","guid":{"rendered":"https:\/\/vizir.az\/?page_id=50881"},"modified":"2019-10-19T19:58:42","modified_gmt":"2019-10-19T19:58:42","slug":"stingray-2-0-portable-level-velocity-logger","status":"publish","type":"page","link":"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/water-wastewater-flow-meter\/open-channel-flow-meters\/stingray-2-0-portable-level-velocity-logger\/","title":{"rendered":"Stingray 2.0 Portable Level-Velocity Logger"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ultimate-heading-999669d522d19e9e8\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-999669d522d19e9e8 uvc-1635  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-999669d522d19e9e8 h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;\">Stingray 2.0 Portable Level-Velocity Logger<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Stingray 2.0 is a compact, battery-powered logger with an ultrasonic sensor. It data logs level, velocity and water temperature readings for flow monitoring through open channels, partially full sewer pipes and surcharged pipes. Use it for flow surveys, I &amp; I studies, stormwater, irrigation water and sewage.<\/p>\n<p>Stingray 2.0 uses a submerged ultrasonic sensor to continuously measure both velocity and level in the channel. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It is hydrodynamically shaped and designed to shed deposits and stringers for reliable operation in sewage, stormwater and stream flow applications. The QZ02L sensor mounts inside the pipe or at the bottom of an open channel. No special compounds, tools or hardware are required. A stainless steel mounting bracket is included.<\/p>\n<p>With 4 standard Alkaline D-cell batteries the Stingray 2.0 will operate up to 4 years! These inexpensive Alkaline batteries are available in stores everywhere and with an extremely low self discharge rate they will reliably power the energy-efficient Stingray 2.0 for the duration of your flow study.<\/p>\n<p>Stingray 2.0 stores 130,000 data points including level, velocity and water temperature. Between readings it powers down to conserve energy.<\/p>\n<p>You can check operation with the built-in LCD bar graph display. It scrolls through level, velocity and temperature readings, plus remaining battery and logger storage capacity. The display turns off automatically after 60 seconds to conserve battery power.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"254\" height=\"300\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/6_SR-Brochure-1-254x300.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"6_SR-Brochure\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/6_SR-Brochure-1-254x300.jpg 254w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/6_SR-Brochure-1-768x907.jpg 768w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/6_SR-Brochure-1-867x1024.jpg 867w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/6_SR-Brochure-1.jpg 1492w\" sizes=\"auto, (max-width: 254px) 100vw, 254px\"  data-dt-location=\"https:\/\/vizir.az\/ru\/6_sr-brochure-3\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div id=\"ultimate-heading-99769d522d19fc6e\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-99769d522d19fc6e uvc-1117  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-99769d522d19fc6e h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">Stingray 2.0 Portable Level-Velocity Logger<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/6_SR-Brochure.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Stingray 2.0 Portable Level-Velocity Logger Stingray 2.0 is a compact, battery-powered logger with an ultrasonic sensor. It data logs level, velocity and water temperature readings for flow monitoring through open channels, partially full sewer pipes and surcharged pipes. Use it for flow surveys, I &amp; I studies, stormwater, irrigation water and sewage. Stingray 2.0 uses&hellip;<\/p>","protected":false},"author":3,"featured_media":0,"parent":50880,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-50881","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50881","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/comments?post=50881"}],"version-history":[{"count":1,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50881\/revisions"}],"predecessor-version":[{"id":50882,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50881\/revisions\/50882"}],"up":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/50880"}],"wp:attachment":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/media?parent=50881"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}