{"id":51101,"date":"2019-09-27T15:04:47","date_gmt":"2019-09-27T15:04:47","guid":{"rendered":"https:\/\/vizir.az\/?page_id=51101"},"modified":"2019-10-20T10:28:48","modified_gmt":"2019-10-20T10:28:48","slug":"thermox-wdg-v-combustion-analyzer","status":"publish","type":"page","link":"https:\/\/vizir.az\/ru\/in-line-combustion-analyzers\/thermox-wdg-v-combustion-analyzer\/","title":{"rendered":"Thermox WDG-V Combustion Analyzer"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div id=\"ultimate-heading-344569d05185d3b99\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-344569d05185d3b99 uvc-7769  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-344569d05185d3b99 h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;\">Thermox WDG-V Combustion Analyzer<\/h2><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety. Low emission burners and aggressive firing control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures, which hold a greater potential for combustion events. Reducing the risk of a combustion event has become a priority and has led to the implementation of Safety Instrumented Systems (SIS). This additional layer of safety is added to the Basic Process Control System.<\/p>\n<p>The WDG-V Combustion Analyzer has been designed to provide an additional layer of safety with the measurement of excess O2, Combustibles and Methane and by using these measurements to ensure the safe operation of the Burner Management System.<\/p>\n<p>There is following modifications: WDG-V, WDG-VC, WDG-VM, WDG-VCM.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_row-o-equal-height vc_row-o-content-middle vc_row-flex\"><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"276\" height=\"300\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1a_wdg-vcm-276x300.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"1a_wdg-vcm\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1a_wdg-vcm-276x300.jpg 276w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1a_wdg-vcm.jpg 634w\" sizes=\"auto, (max-width: 276px) 100vw, 276px\"  data-dt-location=\"https:\/\/vizir.az\/ru\/1a_wdg-vcm-2\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div id=\"ultimate-heading-193269d05185d48a6\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-193269d05185d48a6 uvc-6921  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-193269d05185d48a6 h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">WDG-V Flue Gas Oxygen Analyzer<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1a_wdg-vcm.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"283\" height=\"300\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1b_wdg-vc-283x300.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"1b_wdg-vc\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1b_wdg-vc-283x300.jpg 283w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1b_wdg-vc-768x814.jpg 768w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1b_wdg-vc.jpg 877w\" sizes=\"auto, (max-width: 283px) 100vw, 283px\"  data-dt-location=\"https:\/\/vizir.az\/ru\/1b_wdg-vc-2\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div id=\"ultimate-heading-491569d05185d5859\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-491569d05185d5859 uvc-3343  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-491569d05185d5859 h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">WDG-VC Flue Gas Oxygen and Combustibles Analyzer<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1b_wdg-vc.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"276\" height=\"300\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1c_wdg-v-276x300.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"1c_wdg-v\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1c_wdg-v-276x300.jpg 276w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1c_wdg-v.jpg 634w\" sizes=\"auto, (max-width: 276px) 100vw, 276px\"  data-dt-location=\"https:\/\/vizir.az\/ru\/1c_wdg-v-2\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div id=\"ultimate-heading-612269d05185d6190\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-612269d05185d6190 uvc-6749  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-612269d05185d6190 h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">WDG-V Flue Gas Oxygen Analyzer<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1c_wdg-v.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"103\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1d_wdg-vrm-rack-mount-oxygen-analyzer-300x103.jpg\" class=\"vc_single_image-img attachment-medium\" alt=\"\" title=\"1d_wdg-vrm rack mount oxygen analyzer\" srcset=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1d_wdg-vrm-rack-mount-oxygen-analyzer-300x103.jpg 300w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1d_wdg-vrm-rack-mount-oxygen-analyzer-768x263.jpg 768w, https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1d_wdg-vrm-rack-mount-oxygen-analyzer.jpg 898w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\"  data-dt-location=\"https:\/\/vizir.az\/ru\/1d_wdg-vrm-rack-mount-oxygen-analyzer-2\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div id=\"ultimate-heading-500769d05185d6a50\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-500769d05185d6a50 uvc-9864  uvc-heading-default-font-sizes\" data-hspacer=\"line_only\"  data-halign=\"left\" style=\"text-align:left\"><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-500769d05185d6a50 h5'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h5 style=\"--font-weight:theme;\">WDG-VRM Oxygen Analyzer<\/h5><\/div><div class=\"uvc-heading-spacer line_only\" style=\"topheight:1px;\"><span class=\"uvc-headings-line\" style=\"border-style:solid;border-bottom-width:1px;border-color:#ccc;width:autopx;\"><\/span><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 16px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<a href=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/1d_wdg-vrm-rack-mount-oxygen-analyzer.pdf\" target=\"_blank\"  class=\"vc_single_image-wrapper   vc_box_border_grey\"   ><img decoding=\"async\" class=\"vc_single_image-img\" src=\"https:\/\/vizir.az\/wp-content\/uploads\/2019\/09\/pdf-35x35.png\" width=\"35\" height=\"35\" alt=\"pdf\" title=\"pdf\" loading=\"lazy\"  data-dt-location=\"https:\/\/vizir.az\/ru\/liquid-flow-measurement\/pdmeters\/single-case-meters\/smith-meter-model-sc-13-meter-smith-meter-model-vsc-13-meter\/pdf\/\" \/><\/a>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Thermox WDG-V Combustion Analyzer The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety. Low emission burners and aggressive firing control points to achieve increased efficiency and emission reductions have driven the industry to tighter&hellip;<\/p>","protected":false},"author":3,"featured_media":0,"parent":51065,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-51101","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/51101","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/comments?post=51101"}],"version-history":[{"count":5,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/51101\/revisions"}],"predecessor-version":[{"id":51800,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/51101\/revisions\/51800"}],"up":[{"embeddable":true,"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/pages\/51065"}],"wp:attachment":[{"href":"https:\/\/vizir.az\/ru\/wp-json\/wp\/v2\/media?parent=51101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}